The economical single-phase diesel generator Covax KDE7500E with a maximum power of 5.5 kW is used as a power source for electrical equipment in places with permanent or temporary power outages. The power plant will operate for a long time due to the presence of short-circuit and overload protection. The built-in synchronous electric generator with an automatic regulation system provides reliable output voltage and current frequency. A robust steel frame increases the reliability of the design. Dampers are installed at the base of the generator, which significantly reduces the degree of vibration during operation, and a large installation platform will allow it to be firmly placed in harsh operating conditions. A fuel tank with a volume of up to 12.5 liters ensures continuous operation at 75% load for 8 hours, and a relatively small weight (100 kilograms) and compact dimensions (710x515x630 mm) make it possible to store and move this device without any difficulties.
Model
KDE7500E
Maximum power
5.5 kW
Nominal power
5 kW
Voltage, V
230
Startup type
electric starter
Inverter
No
Maximum current, A
23.9
Rated current in main mode, A
21.7
Specific fuel consumption, l/kW*h
0.4
Fuel consumption at 100% load, l/hour
2
Fuel consumption at 75% load, l/hour
1.5
Fuel consumption at 50% load, l/hour
1
Noise level, dB
83
Protection class
IP23
After the first 5 hours of operation:
Engine oil change
Replacing the oil filter
Cleaning the air filter
Cleaning the fuel filter
Checking and tightening fasteners
Starting and warming up the generator set
Oil and filter disposal
Every 50 engine hours or 3 months (whichever comes first):
Engine oil change
Replacing the oil filter
Cleaning the air filter
Replacing the fuel filter
Checking and tightening fasteners
Cleaning of cooling fins, muffler, piston rods and springs
Starting and warming up the generator set
Oil and filter disposal
Every 100 hours or 6 months (whichever comes first):
Engine oil change
Replacing the oil filter
Replacing the air filter
Replacing the fuel filter
Cleaning the spark arrestor of the muffler
Checking the condition of the spark plug (replacement if necessary)
Checking and tightening fasteners
Cleaning of cooling fins, muffler, piston rods and springs
Starting and warming up the generator set
Oil and filter disposal
Every 300 hours or 12 months (whichever comes first):
Engine oil change
Replacing the oil filter
Replacing the air filter
Replacing the fuel filter
Cleaning the spark arrestor of the muffler
Checking the condition of the spark plug (replacement if necessary)
Checking and adjusting valve clearances
Checking the fuel line (replace if necessary)
Checking and tightening fasteners
Cleaning the combustion chamber
Cleaning of cooling fins, muffler, piston rods and springs
Starting and warming up the generator set
Oil and filter disposal